• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Email: aquaclearinfo@eaiwater.com

Call: (951) 272-8200

Aqua Clear Water Treatment Specialists

Aqua Clear Water Treatment Specialists

Aquaclear Water Treatment Specialists

  • Products
    • Water Treatment Chemistry
      • Reverse Osmosis Chemicals
        • Dechlorination Chemicals
        • Antiscalants
        • Membrane Cleaners
      • Pretreatment & Post-Treatment Chemistry for Water Systems
        • Lead & Copper Removal from Drinking Water
        • Chemical and Dosing Systems
      • Boiler Treatment Chemistry
      • Cooling Tower Treatment Chemistry
      • Coagulants and Flocculants
    • Equipment
      • Membrane Filtration
        • Reverse Osmosis Products
        • Commercial Reverse Osmosis Systems
        • Nanofiltration Systems
        • Ultrafiltration Systems
        • High Recovery Reverse Osmosis (HRRO)
        • Seawater Desalination
        • Capacitive Deionization (CDI)
      • High Purity/Ultrapure
        • Electrodeionization (EDI)
        • Mixed Bed DI
        • Degasification for Water Systems
      • Pretreatment Filtration
        • Media Filtration for Commercial & Industrial Water Purification
        • Multimedia Filters (MMF)
        • Activated Carbon Filters
        • Birm Filter Media
        • Cartridge and Bag Filters
        • Pyrolox Media Replacement
        • Water Softeners
      • Water Disinfection Systems
        • Ultraviolet Sterilizers UV Water Purification
        • Ozone (O3) Generator Systems
      • Wastewater Reuse
        • Membrane Bioreactor (MBR) Wastewater Treatment
        • Wastewater Electrodialysis Reversal (EDR)
        • Ceramic Microfiltration (CMF)
      • Storage & Distribution
      • Clean-In-Place (CIP) Skids
      • Containerized Systems
  • Service and Support
    • Cooling Tower Service
    • Service Contracts and Preventative Maintenance
    • On-Site Startup and Commissioning
    • Membrane Autopsy Services for Water Filtration Systems
    • Laboratory Services
    • Custom Engineered Water Treatment
    • Water Treatment Technical Support
    • Facility Evaluation
  • Applications
    • Industries
      • Food Processing Water Filtration & Disinfection
      • Agricultural Filtration & Reverse Osmosis Systems
      • Institutional Water Treatment Systems
      • Power and Energy
      • Light Industrial Water Treatment
      • Chemicals
      • Municipal
      • Hospitality
      • Aerospace
    • Facility Water Demands
      • Cooling Tower Service
      • Boilers and Hot Water Heater Systems & Maintenance
      • Process Water
      • Water Treatment Process Cleaning
      • Sanitation and Washdown
      • Potable Drinking Water
      • Irrigation
    • Feed Water Quality
      • Municipal Water Treatment & Filtration
      • Well Water
      • Seawater Filtration and Reverse Osmosis
      • Sanitary Wastewater
      • Process Wastewater
  • About
    • Who We Are
    • Career Opportunities
    • Contact Us
    • Distributors Wanted
  • Resources

Degasification for Water Systems

Home » Water Treatment Specialists Products » Equipment » High Purity/Ultrapure » Degasification for Water Systems

In High Purity/Ultrapure water applications when dissolved carbon dioxide (CO2) or oxygen (O2) is present in the water, a Membrane Contactor is often used for degasification between the RO and the EDI (or DI) to reduce the load on the EDI (or DI)

Membrane Contactors are also an alternative to standard Deaerators for removing CO2 and 02 from boiler feedwater.  The removal of CO2 and O2 protects boilers from corrosion.

A Membrane Contactor uses a hollow fiber membrane where the feed water flows across the outside of the hollow fibers while a vacuum applied to the inside of the fibers.  The hydrophobic membrane allows the dissolved gas to pass through the membrane while retaining the water.  The vacuum creates the driving force for dissolved gas in the liquid to pass through the membrane pores and be swept away by the vacuum pump.

Aqua Clear integrates 3M™ Liqui-Cel™ membrane contactors into our high purity RO/EDI packaged systems when the conductivity of CO2 in the RO permeate exceeds the recommended limit for EDI.  The presence of dissolved CO2 will interfere with the exchange capacity of the EDI to achieve ultrapure water.  Similarly, membrane contactors can be used prior to mixed bed DI in order to reduce regeneration chemical usage.

Membrane contactors are modular much like RO vessels and EDI modules and therefore easily scalable to fit the desired flow rate.  We at Aqua Clear Water Treatment Specialists, take pride in everything that we can do for our customers.  From the initial phone call or in-person meeting discussing your water expectations and criteria, thru the custom design and tailored proposal, to the fabrication, installation and commissioning of your system.

Contact Us 

Primary Sidebar

Helpful Links

  • Degasification for Water Systems
  • High Purity/Ultrapure
  • Electrodeionization (EDI)
  • Mixed Bed DI

Footer

Our Mission

Our mission is to provide the best in chemical products, customer service and technical support for the water treatment and reverse osmosis industry.

  • Facebook
  • Twitter
  • YouTube

Contact

  •  (951) 272-8200
  •  aquaclearinfo@eaiwater.com
  •  2790 La Mirada Dr., Vista, CA 92081

Member Company

Association of Waters Technologies - Member Company

Copyright © 2025 · Water Treatment Specialists · All Rights Reserved

  • Aqua Clear